The reliability of VO(2peak)determination in healthy females during an incremental arm ergometry test
Leicht, A.S., Sealey, R.M., and Sinclair, W.H (2009) The reliability of VO(2peak)determination in healthy females during an incremental arm ergometry test. International Journal of Sports Medicine, 30 (7). pp. 509-515.
| PDF (Published Version) - Repository staff only - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader 1292Kb |
View at Publisher Website: http://dx.doi.org/10.1055/s-0029-1202351
Abstract
This study examined the reliability of an incremental arm ergometry (AE) protocol during peak aerobic power (V˙O2peak) determination in healthy females. Fifteen females completed two incremental AE tests to exhaustion, seven to eleven days apart, using a mechanically braked arm ergometer. The initial work rate was 16W and increased by 16W every two minutes until exhaustion. Significant differences between tests were determined by repeated measures ANOVA, and paired t-tests or Wilcoxon signed-rank tests, where appropriate. Reliability was determined by intraclass correlation coefficients (ICC), typical error, coefficient of variation (CV) and measurement bias/ratio and 95% limits of agreement (LOA). Peak cardio-respiratory responses were similar between tests, except for tidal volume (1.95 +/−0.47 vs. 1.81 +/− 0.41 L, P<0.05). Reliability for peak variables was moderate to high (ICC=0.659-0.941; CV≤10%) while LOA were considerable for most variables including V˙O2peak (LOA=0.57L · min-1). Similar peak cardio-respiratory responses, low CV and moderate-high ICC confirmed the reliability of the current incremental AE protocol to be similar to that of prior reported protocols for V˙O2peak determination. Substantial within-participant variability (LOA) for respiratory rate and tidal volume was common during the AE protocol and possibly reflects the influence of respiratory entrainment on reliability that requires further investigation
| ID Code: | 5304 |
|---|---|
| Item Type: | Article (Refereed Research - C1) |
| Related URLs: | |
| Keywords: | arm crank; peak oxygen consumption; upper body exercise; exercise measurement; variability |
| FoR Codes: | 11 MEDICAL AND HEALTH SCIENCES > 1106 Human Movement and Sports Science > 110602 Exercise Physiology @ 100% |
| SEO Codes: | 97 EXPANDING KNOWLEDGE > 970106 Expanding Knowledge in the Biological Sciences @ 70% 92 HEALTH > 9204 Public Health (excl. Specific Population Health) > 920408 Health Status (e.g. Indicators of Well-Being) @ 30% |
| Deposited On: | 24 Sep 2009 10:50 |
| Last Modified: | 11 May 2013 00:44 |
| Downloads: | Total: 3 Last 12 Months: 0 |
| Statistics: | More Statistics |
| Citation Counts with External Providers: | Web of Science: 1 |
Repository Staff Only: item control page