ISO-CADICA: isotopic - continuous, automated dissolved inorganic carbon analyser
Bass, Adrian M., Bird, Michael I., Munksgaard, Niels C., and Wurster, Christopher M. (2012) ISO-CADICA: isotopic - continuous, automated dissolved inorganic carbon analyser. Rapid Communications in Mass Spectrometry, 26 (6). pp. 639-644.
| PDF (Published Version) - Repository staff only - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader 411Kb |
DOI: 10.1002/rcm.6143
View at Publisher Website: http://dx.doi.org/10.1002/rcm.6143
Abstract
RATIONALE: Quantifying the processes that control dissolved inorganic carbon (DIC) dynamics in aquatic systems is essential for progress in ecosystem carbon budgeting. The development of a methodology that allows high-resolution temporal data collection over prolonged periods is essential and is described in this study.
METHODS: A novel sampling instrument that sequentially acidifies aliquots of water and utilises gas-permeable ePTFE tubing to measure the dissolved inorganic carbon (DIC) concentration and δ13CDIC values at sub-hourly intervals by Cavity Ring-down spectrometry (CRDS) is described.
RESULTS: The minimum sensitivity of the isotopic, continuous, automated dissolved inorganic carbon analyser (ISO-CADICA) system is 0.01 mM with an accuracy of 0.008 mM. The analytical uncertainty in δ13CDIC values is proportional to the concentration of DIC in the sample. Where the DIC concentration is greater than 0.3 mM the analytical uncertainty is ±0.1 ‰ and below 0.2 mM stability is < ± 0.3 ‰. The isotopic effects of air temperature, water temperature and CO2 concentrations were found to either be negligible or correctable. Field trials measuring diel variation in δ13CDIC values of coral reef associated sea water revealed significant, short-term temporal changes and illustrated the necessity of this technique.
CONCLUSIONS: Currently, collecting and analysing large numbers of samples for δ13CDIC measurements is not trivial, but essential for accurate carbon models, particularly on small scales. The ISO-CADICA enables on-site, high-resolution determination of DIC concentration and δ13CDIC values with no need for sample storage and laboratory analysis. The initial tests indicate that this system can offer accuracy approaching that of traditional IRMS analysis.
| ID Code: | 21547 |
|---|---|
| Item Type: | Article (Refereed Research - C1) |
| FoR Codes: | 04 EARTH SCIENCES > 0402 Geochemistry > 040203 Isotope Geochemistry @ 100% |
| SEO Codes: | 96 ENVIRONMENT > 9605 Ecosystem Assessment and Management > 960505 Ecosystem Assessment and Management of Forest and Woodlands Environments @ 100% |
| Deposited On: | 14 May 2012 12:46 |
| Last Modified: | 14 May 2013 01:48 |
| Downloads: | Total: 3 Last 12 Months: 0 |
| Statistics: | More Statistics |
| Citation Counts with External Providers: | Web of Science: 3 |
Repository Staff Only: item control page