Comparison of volume and diameter measurement in assessing small abdominal aortic aneurysm expansion examined using computed tomographic angiography

Parr, Adam, Jayaratne, Chanaka, Buttner, Petra, and Golledge, Jonathan (2011) Comparison of volume and diameter measurement in assessing small abdominal aortic aneurysm expansion examined using computed tomographic angiography. European Journal of Radiology, 79 (1). pp. 42-47.

[img]PDF (Published Version) - Repository staff only - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
817Kb

DOI: 10.1016/j.ejrad.2009.12.018

View at Publisher Website: http://dx.doi.org/10.1016/j.ejrad.2009.1...

Abstract

Aim: First we aimed to assess the reproducibility of a computer tomography angiography (CTA) based technique for measuring infra-renal aortic volume and diameter. Second we sought to investigate whether changes in aortic volume and diameter were similar during follow-up.

Materials and methods: A prospective series of 57 patients, with aortic diameter initially measuring between 25 and 55 mm, were assessed with 2 CTAs a median of 14 months apart. Aortic volume and maximum diameter (both axial and orthogonal) were measured by a semi-automated workstation protocol based on previously defined techniques. Intra- and inter-observer reproducibility were assessed by repeat assessment of the initial CTA images of the first 33 patients included in the study, in order to estimate the 95% limits of agreements. Changes in aortic dimensions between the first and follow-up CTA, were defined for volume and diameter separately as changes greater than their respective 95% limits of agreement.

Results: Reproducibility of aortic volume and diameter was excellent with an average coefficient of variation <4%. The median (inter-quartile range) increases in total volume, orthogonal and axial diameters were 4.9 cm3 (0.01–14.18), 1.2 mm (0.40–3.50) and 1.4 mm (−0.15 to 3.55) respectively. Forty-two percent of patients who had increased aortic volume above the 95% limit of agreement did not display corresponding axial or orthogonal diameter changes.

Conclusions: Infra-renal total aortic volume, axial and orthogonal diameter can all be measured reproducibly from CTA. Aortic volume changes are not always reflected by similar changes in diameter and therefore provide complementary information when assessing AAA expansion over time.

ID Code:10679
Item Type:Article (Refereed Research - C1)
Keywords:Abdominal aortic aneurysm; volume; computed tomography
FoR Codes:11 MEDICAL AND HEALTH SCIENCES > 1102 Cardiovascular Medicine and Haematology > 110201 Cardiology (incl Cardiovascular Diseases) @ 100%
SEO Codes:92 HEALTH > 9201 Clinical Health (Organs, Diseases and Abnormal Conditions) > 920103 Cardiovascular System and Diseases @ 100%
Deposited On:05 Aug 2010 15:02
Last Modified:16 Jun 2013 01:13
Downloads:Total: 7
Last 12 Months: 0
Statistics:More Statistics
Citation Counts with External Providers:Web of Science: 3

Repository Staff Only: item control page